• DocumentCode
    1556650
  • Title

    Electrical characteristics of alternative recovery convertors for slip-energy recovery drives

  • Author

    Al Zahawi, B.A.T. ; Jones, B.L. ; Drury, W.

  • Author_Institution
    Cortina Electric Co. Ltd., Watford, UK
  • Volume
    138
  • Issue
    4
  • fYear
    1991
  • fDate
    7/1/1991 12:00:00 AM
  • Firstpage
    193
  • Lastpage
    203
  • Abstract
    The performance characteristics of four different inverter schemes employed in slip-energy recovery drives are analysed and compared. The effects of supply impedance upon inverter current and voltage waveforms are fully accounted for, including the effects of recovery system losses and commutation overlap within the inverter bridges. All three unconventional recovery inverters are found to give markedly better performance than the normal three-phase fully-controlled bridge. In particular, the problems of poor power factor and highly variable reactive power consumption are significantly reduced
  • Keywords
    electric drives; induction motors; invertors; slip (asynchronous machines); commutation overlap; convertors; current waveforms; induction motors; inverter; performance characteristics; reactive power consumption; recovery system losses; slip-energy recovery drives; voltage waveforms;
  • fLanguage
    English
  • Journal_Title
    Electric Power Applications, IEE Proceedings B
  • Publisher
    iet
  • ISSN
    0143-7038
  • Type

    jour

  • Filename
    79338