DocumentCode :
1558091
Title :
Three-dimensional computer-aided diagnosis scheme for detection of colonic polyps
Author :
Yoshida, Hiroyuki ; Näppi, Janne
Author_Institution :
Dept. of Radiol., Chicago Univ., IL, USA
Volume :
20
Issue :
12
fYear :
2001
Firstpage :
1261
Lastpage :
1274
Abstract :
We have developed a three-dimensional (3-D) computer-aided diagnosis scheme for automated detection of colonic polyps in computed tomography (CT) colonographic data sets, and assessed its performance based on colonoscopy as the gold standard. In this scheme, a thick region encompassing the entire colonic wall is extracted from an isotropic volume reconstructed from the CT images in CT colonography. Polyp candidates are detected by first computing of 3-D geometric features that characterize polyps, folds, and colonic walls at each voxel in the extracted colon, and then segmenting of connected components corresponding to suspicious regions by hysteresis thresholding based on these geometric features. We apply fuzzy clustering to these connected components to obtain the polyp candidates. False-positive (FP) detections are then reduced by computation of several 3-D volumetric features characterizing the internal structures of the polyp candidates, followed by the application of discriminant analysis to the feature space generated by these volumetric features. The locations of the polyps detected by our computerized method were compared to the gold standard of conventional colonoscopy. The performance was evaluated based on 43 clinical cases, including 12 polyps determined by colonoscopy. Our computerized scheme was shown to have the potential to detect polyps in CT colonography with a clinically acceptable high sensitivity and a low FP rate.
Keywords :
biological organs; cancer; computerised tomography; feature extraction; fuzzy set theory; hysteresis; image segmentation; medical image processing; virtual reality; clinical cases; clinically acceptable high sensitivity; colonic polyps detection; computerized scheme; discriminant analysis; extracted colon; false-positive detections; feature space; fuzzy clustering; geometric features; hysteresis thresholding; isotropic volume; medical diagnostic imaging; suspicious regions; three-dimensional computer-aided diagnosis scheme; virtual colonoscopy; volumetric features; voxel; Colon; Colonic polyps; Colonography; Computed tomography; Computer aided diagnosis; Data mining; Gold; Image reconstruction; Standards development; Virtual colonoscopy; Algorithms; Cluster Analysis; Colonic Polyps; Colonography, Computed Tomographic; Databases, Factual; Diagnosis, Differential; False Positive Reactions; Humans; Imaging, Three-Dimensional; Models, Biological; Pattern Recognition, Automated; ROC Curve; Radiographic Image Interpretation, Computer-Assisted; Reproducibility of Results; Retrospective Studies; Sensitivity and Specificity; Tomography, X-Ray Computed;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/42.974921
Filename :
974921
Link To Document :
بازگشت