DocumentCode :
1558964
Title :
Assessment of harmonic interference from shipborne converter equipment for compliance with mains quality requirements
Author :
Frankenberg, W. ; Templin, H.
Author_Institution :
Siemens AG, Erlangen, Germany
Volume :
6
Issue :
4
fYear :
1991
fDate :
10/1/1991 12:00:00 AM
Firstpage :
1735
Lastpage :
1739
Abstract :
Interactions of low-frequency harmonics produced by shipborne semiconductor converter equipment with other electric consumers connected to the mains supply system is evaluated. Investigations on board three vessels delivered empirical data for current and voltage harmonics levels under varying ship service conditions. Statistical evaluations lead to the proposal of a model for a mains impedance simulation network. Harmonic response characteristics can be predicted with the assistance of computer simulation
Keywords :
electromagnetic interference; harmonics; power convertors; ships; computer simulation; current harmonic levels; electric consumers; harmonic interference; harmonic response characteristics; low-frequency harmonics; mains impedance simulation network; mains quality requirements; mains supply system; shipborne converter equipment; voltage harmonics levels; Conductors; Current measurement; Frequency; Impedance; Interference; Marine vehicles; Power harmonic filters; Power system harmonics; Testing; Voltage;
fLanguage :
English
Journal_Title :
Power Delivery, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8977
Type :
jour
DOI :
10.1109/61.97714
Filename :
97714
Link To Document :
بازگشت