DocumentCode
1558974
Title
Clean fog rapid procedure test of artificially and naturally polluted HVDC porcelain barrel insulator
Author
Vlastós, Antonios E. ; Ye, Feng ; Boubitsas, Vassiliki
Author_Institution
Chalmers Univ. of Technol., Gothenburg, Sweden
Volume
6
Issue
4
fYear
1991
fDate
10/1/1991 12:00:00 AM
Firstpage
1791
Lastpage
1798
Abstract
The application of the clean fog rapid test procedure to artificially and naturally polluted HVDC porcelain apparatus insulators was studied. The influence of parameters such as salinity (in the case of artificial pollution the influence of the amount of kaolin and salt and of the kaolin/salt ratio in the slurry) and the rate of fog injection was examined. The results from these tests were compared to those obtained with the up and down test procedure. The clean fog rapid test procedure results show that the minimum flashover voltage obtained for an insulator is related both to the salt deposit density (SDD) and to the kaolin to salt ratio (KSR) in the slurry. The results for the cases examined are in agreement with the results obtained with the standard up and down method. A controlled fog test procedure is proposed
Keywords
ceramics; flashover; insulation testing; insulators; HVDC porcelain barrel insulator; apparatus insulators; artificial pollution; clean fog rapid test procedure; fog injection; kaolin; minimum flashover voltage; natural pollution; salinity; salt; salt deposit density; slurry; Flashover; HVDC transmission; Insulation; Insulator testing; Laboratories; Pollution measurement; Porcelain; Senior members; Slurries; Voltage;
fLanguage
English
Journal_Title
Power Delivery, IEEE Transactions on
Publisher
ieee
ISSN
0885-8977
Type
jour
DOI
10.1109/61.97723
Filename
97723
Link To Document