Title :
Monitoring permanent-magnet motor heating with phosphor thermometry
Author :
Allison, Stephen W. ; Cates, Michael R. ; Noel, Bruce W. ; Gillies, George T.
Author_Institution :
Oak Ridge Nat. Lab., TN, USA
fDate :
12/1/1988 12:00:00 AM
Abstract :
The fiber-optic-conveyed, laser-induced fluorescence of a thermographic phosphor was used to measure the surface temperature of the rotor in an operating permanent-magnet motor. The technique uses a pulsed laser to interrogate a surface-bonded film of europium-doped lanthanum oxysulfide for the purpose of determining its temperature-dependent, exponential-decay lifetime. By using digital-delay circuitry to control the measurement systems timing, the authors achieved spatial resolutions of better than 2 mm at speeds of up to 700 rotations/s. The precision of the temperature measurements was 0.3°C. The details of the measurement system are presented and discussed
Keywords :
fibre optics; measurement by laser beam; monitoring; permanent magnet motors; phosphors; temperature measurement; thermometers; La2O2S:Eu; digital-delay circuitry; exponential-decay lifetime; fibre optics; laser-induced fluorescence; monitoring; permanent-magnet motor; phosphor thermometry; pulsed laser; rotor; surface temperature; surface-bonded film; temperature measurements; Fiber lasers; Fluorescence; Heating; Monitoring; Optical pulses; Permanent magnet motors; Phosphors; Rotors; Surface emitting lasers; Temperature measurement;
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on