DocumentCode
1562066
Title
Error analyses of filling control systems for liquid amount-given
Author
Tu, Yaqing ; Zhang, Haitao ; Li, Yongzhi
Author_Institution
Dept. of Autom. Eng., Logistic Eng. Univ., Chongqing, China
Volume
5
fYear
2004
Firstpage
3826
Abstract
It is of instructive significance to systematically analyze the factors that influence the precision of filling control systems for liquid amount-given. The sources of additional errors of volumetric flowmeter and Coriolis mass flowmeter were analyzed in the paper. The factors that influence the filling overshoot and lead to overshoot error were discussed in particular. Then the general system error was expressed and the main approaches to improving the filling precision were summarized. It is indicated that the filling precision of system is mainly decided by the precision of flowmeter and other instruments such as thermometer and manometer on condition that the valve is shut off in advance under low instantaneous flowrate. The influence of overshoot error on the filling precision of system is not remarkable.
Keywords
error analysis; filling; flowmeters; measurement errors; Coriolis mass flowmeter error; error analyses; filling control systems; filling overshoot; filling system precision; overshoot error; volumetric flowmeter errors; Automatic control; Control system analysis; Control systems; Error analysis; Error correction; Filling; Instruments; Logistics; Valves;
fLanguage
English
Publisher
ieee
Conference_Titel
Intelligent Control and Automation, 2004. WCICA 2004. Fifth World Congress on
Print_ISBN
0-7803-8273-0
Type
conf
DOI
10.1109/WCICA.2004.1342204
Filename
1342204
Link To Document