DocumentCode
1563800
Title
Fast dault setection and location for a marine power ststem using system power converters, and active impedance estimation
Author
Wang, Jiacheng ; Sumner, M. ; Thomas, David W. P. ; Geertsma, R.D.
Author_Institution
Sch. of Electical & Electron. Enginnering, Nottingham Univ., Nottingham
fYear
2008
Firstpage
597
Lastpage
601
Abstract
The use of electric drives for propulsion on modern ships means that the correct operation of marine power systems (MPS), especially under fault conditions, is a severe challenge to MPS designers. Many alternative distribution architectures have been proposed, many of which incorporate grid connected power converters to provide an interface to energy storage, or other embedded equipment. The aim of this work is to demonstrate how intelligent use of these distributed power converters may aid with the identification and location of faults on the distribution bus.
Keywords
fault location; marine systems; power convertors; power distribution faults; propulsion; active impedance estimation; distributed power converters; distribution architectures; electric drives; energy storage; fault detection; fault location; marine power system; ship propulsion; fault diagnosis; impedance measurement; marine; power quality;
fLanguage
English
Publisher
iet
Conference_Titel
Power Electronics, Machines and Drives, 2008. PEMD 2008. 4th IET Conference on
Conference_Location
York
ISSN
0537-9989
Print_ISBN
978-0-86341-900-3
Type