DocumentCode :
156528
Title :
Determination of efficient parameters of calibrated one-port vector network analyzers for limited frequency ranges using a short-circuited air line
Author :
Savin, Aleksandr A. ; Guba, Vladimir G.
Author_Institution :
Tomsk State Univ. of Control Syst. & Radioelectron., Tomsk, Russia
fYear :
2014
fDate :
7-13 Sept. 2014
Firstpage :
888
Lastpage :
889
Abstract :
This article presents a new method of accuracy verification of calibrated one-port vector network analyzers based on the least mean square algorithm. The method is of particular interest for significantly limited frequency ranges as well as for costeffective S-parameter measurement systems where the use of conventional ripple test may be impractical and/or relatively expensive. Experimental studies were conducted for few frequency ranges in coaxial measurement environment.
Keywords :
S-parameters; calibration; least mean squares methods; network analysers; S-parameter measurement system; calibration; coaxial measurement environment; least mean square algorithm; one-port vector network analyzer; ripple testing; short-circuited air line; Europe; Vectors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave & Telecommunication Technology (CriMiCo), 2014 24th International Crimean Conference
Conference_Location :
Sevastopol
Print_ISBN :
978-966-335-412-5
Type :
conf
DOI :
10.1109/CRMICO.2014.6959679
Filename :
6959679
Link To Document :
بازگشت