DocumentCode :
1566222
Title :
Control of Neutral-Point-Clamped Converter in Distributed Power Generation to fulfil Low Voltage Ride-Through Requirements
Author :
Alepuz, S. ; Busquets, S. ; Bordonau, J. ; Pontt, Jorge ; Silva, César ; Rodríguez, José
Author_Institution :
Tech. Univ. of Catalonia, Catalonia
fYear :
2007
Firstpage :
2322
Lastpage :
2327
Abstract :
Grid connection requirements established by power system operators have been updated in recent years, in order to include distributed power generation plants operation in the transient operation control of the overall electric power system. Among them, low voltage ride-through requirements demand wind power plant to remain connected to the network in presence of grid voltage dips. It is well-known that grid voltages present positive, negative and zero sequence components under faulty condition, hence regulators based on symmetrical components are well suited to control grid-connected converters. In this work, a neutral-point-clamped topology has been considered as an active front end of a distributed power generation system. In order to achieve balanced grid currents under any grid condition, negative-sequence grid voltage is feed forwarded, working concurrently with the linear quadratic regulator current controller. An outer loop for dc-link voltage control is implemented using a proportional-integral regulator. Power flow mismatch during grid fault condition causes dc-link voltage increase, therefore generator-side regulation is needed to avoid improper dc bus voltage evolution.
Keywords :
PI control; distributed power generation; electric current control; feedforward; linear quadratic control; load flow; power convertors; power generation control; power generation faults; power grids; voltage control; wind power plants; DC-link voltage control; balanced grid currents; distributed power generation; feedforward control; generator-side regulation; grid connection requirements; grid voltage dips; linear quadratic regulator current controller; low-voltage ride-through requirements; negative-sequence grid voltage; neutral-point-clamped converter topology; power flow mismatch; proportional-integral regulator; transient operation control; wind power plant; Distributed power generation; Low voltage; Power system control; Power system stability; Power system transients; Power systems; Regulators; Voltage control; Wind energy generation; Wind power generation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics Specialists Conference, 2007. PESC 2007. IEEE
Conference_Location :
Orlando, FL
ISSN :
0275-9306
Print_ISBN :
978-1-4244-0654-8
Electronic_ISBN :
0275-9306
Type :
conf
DOI :
10.1109/PESC.2007.4342372
Filename :
4342372
Link To Document :
بازگشت