    Multipole imaging source by a cylindrical sensor array

  • Author

    Kildishev, A.V. ; Nyenhuis, J.A. ; Morgan, M.A.

  • Author_Institution
    Purdue University
  • fYear
    2002
  • Firstpage
    293
  • Lastpage
    293
  • Abstract
    Summary form only given. In magnetic multipole imaging, the spheroidal expansions coefficients (c," , snm ) characterizing the magnetostatic potential are obtained from magnetic measurements made outside the source boundary. These harmonic coefficients, known as the multipole image (MI), encapsulate all the major information of the source and may be used for characterization of magnetic sources.