DocumentCode :
157017
Title :
Calorimetric and input-output loss determination of SynRM
Author :
Aarniovuori, L. ; Kolehmainen, J. ; Kosonen, A. ; Niemela, M. ; Pyrhonen, Juha
Author_Institution :
Dept. of Electr. Eng., Lappeenranta Univ. of Technol., Lappeenranta, Finland
fYear :
2014
fDate :
2-5 Sept. 2014
Firstpage :
79
Lastpage :
85
Abstract :
90 kW frequency converter driven synchronous reluctance machine losses are determined simultaneously with the input-output powers and with the calorimetric method. Uncertainty of both measurement methods is analyzed and discussed. Calorimetric measurement system that is capable to determine the losses of the motor frame size up to 315 is introduced.
Keywords :
calorimetry; frequency convertors; loss measurement; reluctance motors; calorimetric loss measurement system; frequency converter; input-output power loss; motor frame size; power 90 kW; synRM; synchronous reluctance machine losses; Current measurement; Frequency measurement; Heating; Loss measurement; Power measurement; Temperature measurement; Uncertainty; Synchronous reluctance motor; calorimeter; measurement; pulse-width-modulation; variable speed drives;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines (ICEM), 2014 International Conference on
Conference_Location :
Berlin
Type :
conf
DOI :
10.1109/ICELMACH.2014.6960162
Filename :
6960162
Link To Document :
بازگشت