Large turbogenerator´s synchronous reactance´s load dependence determined by measurements
Author :
Maljkovic, Z. ; Gasparac, I. ; Pavlica, M.
Author_Institution :
Fac. of Electr. Eng. & Comput., Univ. of Zagreb, Zagreb, Croatia
fYear :
2014
fDate :
2-5 Sept. 2014
Firstpage :
203
Lastpage :
207
Abstract :
The paper presents research on underexcited turbogenerator operation capability. Measurements of basic electrical values for various loads have been carried out in case of 247 MVA turbogenerator. Synchronous reactance for various loads has been determined from measurements. Its influence on underexcited operation limits has been evaluated.
Keywords :
electric reactance measurement; power system measurement; turbogenerators; apparent power 27 MVA; turbogenerator operation capability; turbogenerator synchronous reactance load dependence; underexcited operation limits; Generators; Heating; Reactive power; Stators; Steady-state; Thermal stability; Turbogenerators; Turbogenerators; end region; power system measurements; power system protection; power system stability; underexcited operation;