• DocumentCode
    157168
  • Title

    Fiber Bragg grating technology for hydrogen detection as health monitoring in leakage cases

  • Author

    Saad, Shatina ; Hassine, Lotfi

  • Author_Institution
    Lab. of Adv. Mater. & Quantum Phenomena, Fac. of Sci. of Tunis, Tunis, Tunisia
  • fYear
    2014
  • fDate
    25-27 March 2014
  • Firstpage
    279
  • Lastpage
    283
  • Abstract
    In this research fiber Bragg grating (FBG) sensor for hydrogen detection is presented, especially in leakage cases. Results watch that the presented sensor is unbeatable in compared with the others technologies for hydrogen detection. Resolution, calibration, life time and response time of such sensor are investigating. Precisely in the 0.1%-4% H2 range, we found more than 60pm/1% H2 as resolution and response time of 4-5s. The obtained results indicate that we have a prevention system against hydrogen leakage that leads to disaster. It is efficiency for the health monitoring like in propulsion system fuel tank filled with hydrogen.
  • Keywords
    Bragg gratings; calibration; condition monitoring; fibre optic sensors; gas sensors; hydrogen; H2; calibration; fiber Bragg grating technology; health monitoring; hydrogen detection; hydrogen leakage; life time; response time; sensor resolution; time 4 s to 5 s; Fiber gratings; Hydrogen; Optical fiber sensors; Optical fibers; Sensitivity; Time factors; calibration; fiber Bragg grating; hydrogen detection; leakage; life time; prevention system; propulsion system fuel tank; resolution; response time;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Green Energy, 2014 International Conference on
  • Conference_Location
    Sfax
  • Print_ISBN
    978-1-4799-3601-4
  • Type

    conf

  • DOI
    10.1109/ICGE.2014.6835435
  • Filename
    6835435