• DocumentCode
    157209
  • Title

    Online controller modifying of a six-phase induction generator in phase opening occurrences

  • Author

    Taherzadeh, Mahmoud ; Carriere, S. ; Betin, F. ; Joorabian, M. ; Kianinezhad, Reza ; Capolino, G.A.

  • Author_Institution
    Dept. of Electr. Eng., Shahid Chamran Univ. of Ahwaz, Ahwaz, Iran
  • fYear
    2014
  • fDate
    2-5 Sept. 2014
  • Firstpage
    836
  • Lastpage
    842
  • Abstract
    This study presents field oriented control of a squirrel cage six-phase induction generator (SC6PIG) when a phase fault is detected in order to minimize output power oscillations during phase opening. An unbalanced structure of squirrel cage six-phase induction machine (SC6PIM) has been modeled to analyze healthy and faulty conditions of the machine. According to the unbalanced structure of the machine, a suitable controller is defined in phase missing condition to minimize power oscillations. After fault detection by using a dedicated system, the controller used in healthy condition is switched to a new one regarding to the fault situation. For each controller, appropriate initial conditions are chosen to minimize the transient behavior of switching process between healthy and faulty controllers. The whole proposed system has been implemented on an experimental set up including of a six-phase induction generator coupled with a permanent magnet direct current (dc) motor. Experimental results prove the feasibility and show the improvement of power quality when the controller is modified in phase missing conditions. The experimental results are presented for one phase missing and they can also be obtained for two or three phases missing conditions.
  • Keywords
    DC motors; asynchronous generators; fault diagnosis; machine vector control; permanent magnet motors; power supply quality; SC6PIG; faulty conditions; faulty controllers; field oriented control; healthy conditions; healthy controllers; online controller; permanent magnet direct current motor; phase fault detection; phase missing condition; phase opening occurrences; power oscillations; power quality; squirrel cage six-phase induction generator; switching process; transient behavior; unbalanced structure; Fault detection; Generators; Oscillators; Rotors; Stators; Switches; IRFOC; online controller modifying; phase missing; power oscillation reduction; six phase induction generator;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines (ICEM), 2014 International Conference on
  • Conference_Location
    Berlin
  • Type

    conf

  • DOI
    10.1109/ICELMACH.2014.6960278
  • Filename