• DocumentCode
    157238
  • Title

    Comparison of no-load and load core losses for a wide range of nominal power induction motors

  • Author

    Dems, M. ; Komeza, K.

  • Author_Institution
    Inst. of Mechatron. & Inf. Syst., Tech. Univ. of Lodz, Lodz, Poland
  • fYear
    2014
  • fDate
    2-5 Sept. 2014
  • Firstpage
    1024
  • Lastpage
    1030
  • Abstract
    This paper presents a comparison of no-load and load losses for six different nominal power induction motors ranging from 3 kW to 280 kW. For loss calculations, field-circuit and analytical methods are used. The results show a significant increase in core losses concomitant with motor load increases. Additionally, analytical methods were employed to calculate the curves of core losses versus load power.
  • Keywords
    cores; induction motors; losses; analytical method; field circuit method; no-load core loss; nominal power induction motors; power 3 kW to 280 kW; Core loss; Harmonic analysis; Induction motors; Loss measurement; Rotors; Stator cores; circuit modelling; finite element method; induction motors; magnetic losses;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines (ICEM), 2014 International Conference on
  • Conference_Location
    Berlin
  • Type

    conf

  • DOI
    10.1109/ICELMACH.2014.6960307
  • Filename
    6960307