DocumentCode :
157440
Title :
Delta connected induction motor drive analysis under open switch converter fault
Author :
Pallis, Ioannis K. ; Kappatou, Joya C.
Author_Institution :
Dept. of Electr. & Comput. Eng., Univ. of Patras, Rion Achaia, Greece
fYear :
2014
fDate :
2-5 Sept. 2014
Firstpage :
2355
Lastpage :
2361
Abstract :
This paper investigates an electrical induction motor drive system under open switch inverter fault. The finite element analysis (FEA) is used in order to specify the effects of the open switch fault on the induction motor. The winding of the induction motor was considered delta connected. The consequences of the unbalanced inverter supply on the developed phase and line currents as well as the electromagnetic torque are studied. The unbalanced distribution, over the cross section of the machine, of the magnetic flux density time harmonics is presented. Moreover a comparison of the efficiency before and after the fault is made.
Keywords :
finite element analysis; induction motor drives; invertors; magnetic flux; power conversion harmonics; switching convertors; FEA; delta connected induction motor drive analysis; electrical induction motor drive system; electromagnetic torque; finite element analysis; inverter supply; line currents; magnetic flux density time harmonics; open switch converter fault; open switch inverter fault; Circuit faults; Electromagnetics; Harmonic analysis; Induction motors; Inverters; Switches; Torque; Induction motors; fault tolerance; finite element analysis; pulse width modulation converters; variable speed drives;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines (ICEM), 2014 International Conference on
Conference_Location :
Berlin
Type :
conf
DOI :
10.1109/ICELMACH.2014.6960515
Filename :
6960515