DocumentCode :
1574693
Title :
The technique of detecting the dispensed volume in gene transfer system
Author :
Ling, Zhang ; Yun, Zhang ; Yimin, Yang ; Hanbin, Cen ; Yingxia, Zhang
Author_Institution :
Autom. Inst., Guangdong Univ. of Technol., Guangzhou, China
Volume :
4
fYear :
2004
Firstpage :
3747
Abstract :
An in-line detecting system is presented in this paper, which utilizes scanning tunneling microscope (STM) technology to detect accurately the dispensed volume in gene transfer system, and then a close-loop controlling system for the dispensed volume can be constructed based on this detecting system. The following experiment results show the sensitivity of this detecting system is pleased with micro-injection operation and prove it is a applicable method for detecting.
Keywords :
closed loop systems; genetics; scanning tunnelling microscopy; close-loop controlling system; dispensed volume detection; gene transfer system; in-line detecting system; microinjection operation; scanning tunneling microscope technology; Control systems; Microinjection; Microscopy; Tunneling;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Intelligent Control and Automation, 2004. WCICA 2004. Fifth World Congress on
Print_ISBN :
0-7803-8273-0
Type :
conf
DOI :
10.1109/WCICA.2004.1343300
Filename :
1343300