• DocumentCode
    1578275
  • Title

    Investigation of explosions in a number of Ex-certified handlamps and an examination of relevant safety standards

  • Author

    Tolson, P. ; Widginton, D.W.

  • fYear
    1988
  • Firstpage
    46
  • Lastpage
    49
  • Abstract
    Over a period of less than two years five handlamps of the same type have exploded. In each case the front end of the lamp blew off, fortunately injuring no one and causing little damage. The handlamps were properly manufactured and correctly certified to UK and European Standards that indicated that they were safe for use in flammable atmospheres (including hydrogen). The authors describe the incidents and their investigation. They also discuss some of the constructional requirements of the standards and how they relate to these incidents
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Electrical Safety in Hazardous Areas, 1988., Fourth International Conference on
  • Conference_Location
    London
  • Print_ISBN
    0-85296-370-X
  • Type

    conf

  • Filename
    9537