DocumentCode :
1578869
Title :
Measurement of voltage rise curves due to gap discharge using coupled transmission lines in distributed constant line system
Author :
Kawamata, Ken ; Minegishi, Shigeki ; Haga, Akira ; Sat, Risaburo
Author_Institution :
Hachinohe Inst. of Technol., Japan
fYear :
1997
Firstpage :
489
Lastpage :
492
Abstract :
Very fast voltage rise curves due to gap discharge were examined to discuss an EMI source. The measurement system consists of a distributed constant line system, because the voltage transients were very rapid. A characteristic of the gap electrode, which has a matched impedance for the distributed constant line system, was investigated in the frequency range below 5 GHz. The voltages of the power source in the experiment were 510 V and 800 V because Paschen´s law holds its stability in the air condition. It was confirmed that the measurement method enables one to measure high speed voltage rise curves of about 100 ps
Keywords :
discharges (electric); electrodes; electromagnetic compatibility; electromagnetic interference; impedance matching; transient analysis; transients; transmission lines; voltage measurement; 510 V; 800 V; EMC; EMI source; Paschen´s law; coupled transmission lines; distributed constant line system; experiment; frequency range; gap discharge; gap electrode; matched impedance; measurement method; measurement system; power source; voltage rise curves measurement; voltage transients; Coupled transmission lines;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility Proceedings, 1997 International Symposium on
Conference_Location :
Beijing
Print_ISBN :
0-7803-3608-9
Type :
conf
DOI :
10.1109/ELMAGC.1997.617195
Filename :
617195
Link To Document :
بازگشت