DocumentCode :
1579687
Title :
A PDA-based Network for Telemonitoring Asthma Triggering Gases in the El Paso School Districts of the US - Mexico Border Region
Author :
Shenoy, Namdev ; Nazeran, Homer
Author_Institution :
Dept. of Electr. & Comput. Eng., Texas Univ., El Paso, TX
fYear :
2006
Firstpage :
5186
Lastpage :
5189
Abstract :
In this paper we describe the application of a personal digital assistant (PDA) or pocket PC as an effective communication device to telemonitor levels of asthma triggering gases collected from a remote location under test to a workstation which has a personal computer (PC) running on Windows XPreg as the operating system. The Bluetoothreg features of the PDA are explored to transmit data collected by a Directtrade Sense Tox toxic gas monitor equipped with five toxic gas probes and one temperature sensor in real time, thereby making this telemonitoring system an innovative instrument in monitoring levels of asthma triggering gases in the El Paso-border metropolitan region, a region in which asthma is highly prevalent especially in children. At the workstation or fixed location these readings are displayed using a custom made, user friendly graphical user interface (GUI) developed using software tools like action scripting with Macromediareg Flashtrade. The growing advancement in technology and ever diminishing sizes of handheld devices encouraged us to opt for this configuration. Moreover, the PDA and toxic gas monitor were also chosen for their light weight, portability, flexibility, low cost and data collection and transmission capabilities
Keywords :
biomedical equipment; diseases; gas sensors; graphical user interfaces; medical computing; notebook computers; paediatrics; patient monitoring; pneumodynamics; telemedicine; temperature sensors; Bluetooth features; Direct Sense Tox; El Paso-border metropolitan region; Flash; Macromedia; PDA-based network; Windows XP; asthma; asthma triggering gases; communication device; graphical user interface; operating system; personal digital assistant; pocket personal computer; software tools; telemonitoring; temperature sensor; toxic gas monitor; toxic gas probes; Application software; Communication effectiveness; Gases; Graphical user interfaces; Microcomputers; Monitoring; Operating systems; Personal digital assistants; System testing; Workstations; Bluetooth®; Telemonitoring; asthma triggers; biomedical instrumentation; graphical user interface; personal digital assistants (PDAs); wireless communication;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2005. IEEE-EMBS 2005. 27th Annual International Conference of the
Conference_Location :
Shanghai
Print_ISBN :
0-7803-8741-4
Type :
conf
DOI :
10.1109/IEMBS.2005.1615646
Filename :
1615646
Link To Document :
بازگشت