DocumentCode :
1580114
Title :
Balancing procedure for an IVD bridge
Author :
Avramov-Zamurovic, Svetlana ; Waltrip, Bryan ; Stricklett, Ken ; Koffman, Andrew
Author_Institution :
Dept. of Weapons & Syst. Eng., United States Naval Acad., Annapolis, MD, USA
Volume :
2
fYear :
2003
Firstpage :
1599
Abstract :
This paper presents a detector balancing procedure for a bridge based on the straddling method that is used to calibrate inductive voltage dividers (IVDs). A bridge of this type requires multiple, simultaneous balances, which, due to interactions between the various circuit networks involved, are difficult to achieve in practice. An algorithm will be demonstrated that achieves balances on the order of 1 part in 109.
Keywords :
bridge circuits; calibration; voltage dividers; IVD bridge; bridge balance; circuit networks; detector balancing procedure; inductive voltage dividers; injection; straddling bridge; straddling method; Bridge circuits; Change detection algorithms; Current measurement; Detectors; Iterative algorithms; Iterative methods; NIST; Virtual colonoscopy; Voltage; Weapons;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Instrumentation and Measurement Technology Conference, 2003. IMTC '03. Proceedings of the 20th IEEE
ISSN :
1091-5281
Print_ISBN :
0-7803-7705-2
Type :
conf
DOI :
10.1109/IMTC.2003.1208019
Filename :
1208019