DocumentCode :
1580680
Title :
A study on the burn-in test of charger with load bank elimination
Author :
Lin, C.E. ; Tsai, M.T. ; Tsai, W.I. ; Huang, C.L.
Author_Institution :
Dept. of Electr. Eng., Nat. Cheng Kung Univ., Tainan, Taiwan
fYear :
1995
Firstpage :
72
Lastpage :
77
Abstract :
For burn-in test of battery charger, heaters are generally used as loads, and significant energy will be wasted. In order to save energy and reduce the test cost, a load consumption free method is expected. In this paper, a new control strategy of three-phase PWM DC/AC inverter using current-mode control is proposed for this purpose. Replacing the heat load by a DC/AC inverter, the energy is fedback to the utility system. The proposed method can be used to test chargers or other DC equipments. In this paper, the theoretical results are verified both by simulated and experimental results in a 5 KVA laboratory prototype system
Keywords :
DC-AC power convertors; PWM power convertors; battery chargers; circuit testing; rectifiers; 3-phase inverter; 5 KVA laboratory prototype system; PWM DC/AC inverter; battery charger; burn-in test; current-mode control; load bank elimination; Costs; Electronic equipment testing; Equations; Inverters; Laboratories; Load flow; Power electronics; Pulse width modulation; Resistors; System testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industrial Automation and Control: Emerging Technologies, 1995., International IEEE/IAS Conference on
Conference_Location :
Taipei
Print_ISBN :
0-7803-2645-8
Type :
conf
DOI :
10.1109/IACET.1995.527542
Filename :
527542
Link To Document :