Title :
Slurry density measurements using low-cost spectrum analysers
Author :
Eren, Halit ; Goh, James
Author_Institution :
Sch. of Electr. & Comput. Eng., Curtin Univ. of Technol., WA, Australia
fDate :
6/15/1905 12:00:00 AM
Abstract :
The frequency and amplitude of signals generated by the electrodes of DC type flowmeters are demonstrated to be affected by the particles in slurries flowing in closed pipes. A low cost spectrum analyser has been configured to extract the frequency component which then can be used to monitor density of the slurry.
Keywords :
density measurement; flow measurement; flowmeters; pipe flow; spectral analysers; DC type flowmeters; amplitude; closed pipes; cost; electrodes; frequency; slurry density measurement; spectrum analysers; Circuit testing; Density measurement; Electrodes; Frequency; Magnetic analysis; Monitoring; Signal analysis; Signal generators; Signal processing; Slurries;
Conference_Titel :
Industrial Electronics, 1993. Conference Proceedings, ISIE'93 - Budapest., IEEE International Symposium on
Conference_Location :
Budapest, Hungary
Print_ISBN :
0-7803-1227-9
DOI :
10.1109/ISIE.1993.268732