• DocumentCode
    1582938
  • Title

    Torque ripple in synchronous machine driven by a three-phases PWM converter

  • Author

    Robet, P. Ph ; Gautier, M. ; Bergmann, C.

  • Author_Institution
    Lab. d´´Autom., Nantes Univ., France
  • fYear
    1995
  • Firstpage
    122
  • Lastpage
    127
  • Abstract
    In this paper we propose to find the theoretical torque ripple calculation for a synchronous machine without a salient pole due to defaults which can occur with a three phase PWM driver. The following calculation is done with a fixed input control voltage, which can be continuous or sampled and held. As a result, information about disturbing harmonics for a steady state point can be found for a machine with an unconnected neutral point and without saturation
  • Keywords
    PWM power convertors; power system harmonics; synchronous motor drives; torque; disturbing harmonics; fixed input control voltage; steady state; synchronous machine; three phase PWM drive; three-phase PWM converter; torque ripple; unconnected neutral point; Centralized control; Frequency conversion; Harmonic analysis; Information analysis; Pulse width modulation; Pulse width modulation converters; Switching frequency; Synchronous machines; Torque control; Voltage control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial Automation and Control: Emerging Technologies, 1995., International IEEE/IAS Conference on
  • Conference_Location
    Taipei
  • Print_ISBN
    0-7803-2645-8
  • Type

    conf

  • DOI
    10.1109/IACET.1995.527550
  • Filename
    527550