• DocumentCode
    1582973
  • Title

    Development of highly stabilized & high precision power supply for KCCH cyclotron magnet

  • Author

    Song, I.H. ; Shin, H.S. ; Choi, C.H. ; Chai, J.S. ; Kim, Y.S.

  • Author_Institution
    POSCON Corp. R&D Center, Korea Univ., Seoul, South Korea
  • Volume
    2
  • fYear
    2001
  • Firstpage
    1189
  • Abstract
    110 V/600 A, highly stabilized power supply have been installed at the Korea Cancer Center Hospital (KCCH) in Seoul, to energize water-cooled, resistive, high field research magnet for cyclotron. The power supply achieves a long term current stability of 20 ppm over one hour period with a short term ripple and noise variation of <20 ppm over a time period of one cycle. Power supply consists of a three-winding transformer, 12-pulse thyristor converter with interphase reactor, and a passive filter and a pass bank MOSFETs regulator. Various test results taken during the commissioning phase with a 70 kW resistive load and results taken with the research magnet for cyclotron are shown. This paper presents the detailed design of the power supply components. Problems with the power supply design and solutions are also presented. Some suggestions on how to improve the performance of these supplies are outlined.
  • Keywords
    cyclotrons; magnets; power supplies to apparatus; pulsed power supplies; 110 V; 600 A; 70 kW; MOSFETs regulator; cyclotron; cyclotron magnet; highly stabilized high precision power supply; interphase reactor; long term current stability; passive filter; power supply components; resistive load; three-winding transformer; thyristor converter; water-cooled resistive high field research magnet; Cancer; Cyclotrons; Hospitals; Inductors; MOSFETs; Passive filters; Power supplies; Regulators; Stability; Thyristors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pulsed Power Plasma Science, 2001. PPPS-2001. Digest of Technical Papers
  • Conference_Location
    Las Vegas, NV, USA
  • Print_ISBN
    0-7803-7120-8
  • Type

    conf

  • DOI
    10.1109/PPPS.2001.1001759
  • Filename
    1001759