Title :
PD detection: a new approach
Author :
Carminati, E. ; Lazzaroni, M.
Author_Institution :
Dipt. di Elettrotecnica, Politecnico di Milano, Italy
Abstract :
Electric discharges that not completely bridge the electrodes are named partial discharges. The apparent charge is the charge displacement in the leads of the specimen subsequent a PD event. In order to obtain a good evaluation of the discharge characteristics a high-sensitivity and high accuracy detector has been developed using a mixed analog and digital signal processing technique. Direct analog integration of current pulse is used to achieve apparent charge. Then an analog to digital conversion of signal is performed and the results are is: stored for subsequent mathematical treatments. The system is configured for the evaluation of all parameters listed in lEC270 standard. The system gives information typical of both “time resolved systems” and “phase resolved systems”
Keywords :
analogue-digital conversion; charge measurement; partial discharges; ADC; accuracy; analog to digital conversion; apparent charge; charge displacement; current pulse; direct analog integration; electric discharges; lEC270 standard; mixed signal; partial discharges; phase resolved systems; time resolved system; Band pass filters; Capacitance; Circuit testing; Current measurement; Frequency; Impedance measurement; Narrowband; Partial discharges; Pulse measurements; Wideband;
Conference_Titel :
Instrumentation and Measurement Technology Conference, 1998. IMTC/98. Conference Proceedings. IEEE
Conference_Location :
St. Paul, MN
Print_ISBN :
0-7803-4797-8
DOI :
10.1109/IMTC.1998.676823