• DocumentCode
    1587693
  • Title

    PD detection: a new approach

  • Author

    Carminati, E. ; Lazzaroni, M.

  • Author_Institution
    Dipt. di Elettrotecnica, Politecnico di Milano, Italy
  • Volume
    2
  • fYear
    1998
  • Firstpage
    738
  • Abstract
    Electric discharges that not completely bridge the electrodes are named partial discharges. The apparent charge is the charge displacement in the leads of the specimen subsequent a PD event. In order to obtain a good evaluation of the discharge characteristics a high-sensitivity and high accuracy detector has been developed using a mixed analog and digital signal processing technique. Direct analog integration of current pulse is used to achieve apparent charge. Then an analog to digital conversion of signal is performed and the results are is: stored for subsequent mathematical treatments. The system is configured for the evaluation of all parameters listed in lEC270 standard. The system gives information typical of both “time resolved systems” and “phase resolved systems”
  • Keywords
    analogue-digital conversion; charge measurement; partial discharges; ADC; accuracy; analog to digital conversion; apparent charge; charge displacement; current pulse; direct analog integration; electric discharges; lEC270 standard; mixed signal; partial discharges; phase resolved systems; time resolved system; Band pass filters; Capacitance; Circuit testing; Current measurement; Frequency; Impedance measurement; Narrowband; Partial discharges; Pulse measurements; Wideband;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference, 1998. IMTC/98. Conference Proceedings. IEEE
  • Conference_Location
    St. Paul, MN
  • ISSN
    1091-5281
  • Print_ISBN
    0-7803-4797-8
  • Type

    conf

  • DOI
    10.1109/IMTC.1998.676823
  • Filename
    676823