DocumentCode
1587980
Title
Early detection of deteriorations affecting neutrons boron detectors
Author
Domenech, T. ; Hamrita, H. ; Normand, S. ; Daviaud, J.P. ; Laroche, M.
Author_Institution
Lab. Capteur et Archit. Electroniques, CEA, Gif-sur-Yvette, France
fYear
2011
Firstpage
1
Lastpage
4
Abstract
The objective of these studies is to design and to industrialize a new device taking back the features of the actual system of control of boron detectors and updating them by adding some analysis of the pulses shapes for predictive maintenance.
Keywords
neutron detection; proportional counters; neutron boron detectors; predictive maintenance; pulses shapes; Argon; Boron; Detectors; Filling; Neutrons; Radiation detectors; Shape; Boron neutron detector; gas ionization and pulse shape analysis;
fLanguage
English
Publisher
ieee
Conference_Titel
Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA), 2011 2nd International Conference on
Conference_Location
Ghent
Print_ISBN
978-1-4577-0925-8
Type
conf
DOI
10.1109/ANIMMA.2011.6172911
Filename
6172911
Link To Document