  • Title

    Research on the coupling heart electric field using passive human body detection system

  • Author

    Yan, Zhang ; Lixin, Xu

  • Author_Institution
    State Key Lab. of Mechatron. Eng. & Control, Beijing Inst. of Technol., Beijing, China
  • Volume
    2
  • fYear
    2011
  • Firstpage
    352
  • Lastpage
    356
  • Abstract
    An analysis of the coupling heart electric field is a pivotal step in the human body detection system which target for the heart coupling electric field between the operator and the detected living human. In this paper, the double-human heart coupling electric field is discussed and the three-dimensional finite element method is used to analytically solve that problem. Firstly, we described the principle of the single human cardiact electric dipole equal effects. Then, the double-human coupling heart electric field is analyzed. Finally, the three-dimensional finite element method is used for simulating and calculating the coupling heart electric field. The three different typical coupling heart electric fields are shown in the result. The conclusion of this paper is the most significant studies of the passive human body detection technique.
  • Keywords
    bioelectric phenomena; cardiology; finite element analysis; 3D finite element method; coupling heart electric field; human cardiac electric dipole equal effects; passive human body detection system; Couplings; Electric fields; Electric potential; Force; Heart; Humans; Myocardium; Three-dimensional finite element; coupling heart electric field; heart electric dipole; human body detection system;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electronic Measurement & Instruments (ICEMI), 2011 10th International Conference on
  • Conference_Location
    Chengdu
  • Print_ISBN
    978-1-4244-8158-3
  • Type

    conf

  • DOI
    10.1109/ICEMI.2011.6037833
  • Filename