DocumentCode
158889
Title
Comparative study of copper and aluminium conductors - Future cost effective PM machines
Author
Wrobel, Rafal ; Salt, Daniel ; Simpson, Nick ; Mellor, Phil H.
Author_Institution
Dept. of Electr. & Electron. Eng., Univ. of Bristol, Bristol, UK
fYear
2014
fDate
8-10 April 2014
Firstpage
1
Lastpage
6
Abstract
This paper investigates the use of aluminium (Al) as an alternative to the more common copper (Cu) conductors used in the construction of future cost effective PM machines. The use of Al conductors in the context of PM machine design has not been widely explored or reported in the literature. The main focus of this research has been placed on the power loss generated at ac operation and associated thermal and heat transfer phenomena, which are essential to understand when a compact and efficient machine design utilising Al conductors is considered.
Keywords
aluminium; conductors (electric); copper; electrical resistivity; heat losses; heat transfer; machine windings; permanent magnet machines; AC power loss component; DC power loss component; PM machine design; aluminium conductor material; copper conductor material; heat transfer phenomena; thermal transfer phenomena; winding electrical resistivity; winding material; winding power loss generation; winding temperature; Copper and aluminium winding conductors; PM machines; Thermal effects; Winding ac power loss; Winding construction;
fLanguage
English
Publisher
iet
Conference_Titel
Power Electronics, Machines and Drives (PEMD 2014), 7th IET International Conference on
Conference_Location
Manchester
Electronic_ISBN
978-1-84919-815-8
Type
conf
DOI
10.1049/cp.2014.0292
Filename
6836778
Link To Document