• DocumentCode
    158948
  • Title

    Automated qualification and analysis of protective spark gaps for DC accelerators

  • Author

    Banerjee, Sean ; Rajan, R.N. ; Dewangan, S. ; Sharma, D.K. ; Patel, Rahul ; Bakhtsingh, R.I. ; Gond, S. ; Waghmare, Anandghan ; Thakur, Nitin ; Mittal, Kailash Chandra

  • Author_Institution
    Accel. & Pulse Power Div., Bhabha Atomic Res. Centre, Mumbai, India
  • fYear
    2014
  • fDate
    Sept. 28 2014-Oct. 3 2014
  • Firstpage
    653
  • Lastpage
    655
  • Abstract
    Protective spark gaps are used in the high voltage multiplier column of a 3 MeV DC Accelerator to prevent excessive voltage build-ups. Precise gap of 5 mm is maintained between the electrodes in these spark gaps for obtaining 120kV±5kV in 6kg/cm2 SF6 environment which is the dielectric medium. There are 74 such spark gaps used in the multiplier. Each spark gap has to be qualified for electrical performance before fitting in the accelerator to ensure reliable operation. As the breakdown voltage stabilizes after a large number of sparks between the electrodes, the qualification process becomes time consuming and cumbersome. For qualifying large number of spark gaps an automatic breakdown analysis setup has been developed. This setup operates in air, a dielectric medium. The setup consists of a flyback topology based high voltage power supply with maximum rating of 25 k V. This setup works in conjuction with spark detection and automated shutdown circuit. The breakdown voltage is sensed using a peak detector circuit. The voltage breakdown data is recorded and statistical distribution of the breakdown voltage has been analyzed. This paper describes details of the diagnostics and the spark gap qualification process based on the experimental data.
  • Keywords
    SF6 insulation; electric breakdown; electrodes; power supplies to apparatus; reliability; spark gaps; statistical distributions; DC accelerators; SF6 environment; automated qualification; automated shutdown circuit; automatic breakdown analysis; breakdown voltage; dielectric medium; distance 5 mm; electrical performance; electrodes; electron volt energy 3 MeV; flyback topology; high voltage multiplier column; high voltage power supply; maximum rating; peak detector circuit; protective spark gaps; spark detection; statistical distribution; voltage 120 kV; voltage 25 kV; Discharges (electric); Electrodes; Power supplies; Spark gaps; Sparks; Topology;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Discharges and Electrical Insulation in Vacuum (ISDEIV), 2014 International Symposium on
  • Conference_Location
    Mumbai
  • Print_ISBN
    978-1-4799-6750-6
  • Type

    conf

  • DOI
    10.1109/DEIV.2014.6961767
  • Filename
    6961767