DocumentCode :
1589669
Title :
A Real-time Display Method for Ultrasound Color Flow Velocity Estimation
Author :
Jianqi, Deng ; Liu Dong C ; Jiliu, Zhou
Author_Institution :
Sichuan Univ., Chengdu
fYear :
2006
Firstpage :
6575
Lastpage :
6578
Abstract :
This paper proposes a new way for ultrasound color flow velocity estimation and display. This method sets up a mapping table which directly relates to the dynamic range of the velocity display by using an inverse mapping instead of calculating the arctangent value directly. This method is ideal for software implementation and offers an interactive way to user for changing the dynamic range of flow velocity to increase the display resolution
Keywords :
biomedical ultrasonics; haemodynamics; image colour analysis; image motion analysis; image resolution; medical image processing; display resolution; inverse mapping; real-time display method; ultrasound color flow velocity estimation; Autocorrelation; Biomedical imaging; Blood; Displays; Doppler shift; Dynamic range; Frequency estimation; Signal resolution; Table lookup; Ultrasonic imaging; color Doppler; color flow image; color flow mapping;