Title :
Least coupling paths model for non-contact EMI base on lump element approach in switch mode converter
Author :
Poon, N.K. ; Liu, C.P. ; Pong, M.H.
Author_Institution :
Power Electron. Lab, Univ. of Hong Kong, China
fDate :
6/23/1905 12:00:00 AM
Abstract :
A simplified physical model of a switch mode power converter concludes a minimum of six equivalent physical coupling paths, least coupling paths (LCP), using lump elements approach through noncontact EMI coupling mechanism to the terminals of LISN. Simulation shows both inductive and capacitive coupling through each path may produce substantial EMI measured by a LISN. This physical model is good for understanding, diagnosis and emission estimation
Keywords :
electromagnetic interference; equivalent circuits; lumped parameter networks; power convertors; printed circuits; switched mode power supplies; LISN terminals; capacitive coupling; equivalent physical coupling paths; inductive coupling; least coupling paths; lump elements approach; noncontact EMI coupling mechanism; switch mode power converter; Circuit noise; Circuit simulation; Computational modeling; Coupling circuits; Electromagnetic interference; Physics computing; Power electronics; Switches; Switching converters; Voltage;
Conference_Titel :
Power Electronics Specialists Conference, 2001. PESC. 2001 IEEE 32nd Annual
Conference_Location :
Vancouver, BC
Print_ISBN :
0-7803-7067-8
DOI :
10.1109/PESC.2001.954176