DocumentCode
1590042
Title
High-frequency oscillations in a power transformer
Author
Dernetriades, G.D. ; Manias, S.N. ; Ranstad, P.
Author_Institution
Power Eng. Dept., ABB Corp. Res., Vasteras, Sweden
Volume
2
fYear
2001
fDate
6/23/1905 12:00:00 AM
Firstpage
612
Abstract
Power transformers are widely used as step-up or step-down devices and they can offer galvanic isolation between the input of the power supply and the output. When the operating frequency is considerably high, transformer parasitics are of importance. Interleaving of the transformer windings causes a reduction of the leakage inductance. However, the winding capacitance and the stray capacitance increases due to the good proximity of the windings achieved by interleaving
Keywords
capacitance; circuit oscillations; inductance; power supplies to apparatus; power transformers; transformer windings; high-frequency oscillations; leakage inductance; operating frequency; power transformers; step-down devices; step-up devices; stray capacitance; transformer parasitics; transformer windings interleaving; winding capacitance; Conducting materials; Dielectrics and electrical insulation; Frequency; Galvanizing; Inductance; Interleaved codes; Parasitic capacitance; Permittivity; Power supplies; Power transformers;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics Specialists Conference, 2001. PESC. 2001 IEEE 32nd Annual
Conference_Location
Vancouver, BC
ISSN
0275-9306
Print_ISBN
0-7803-7067-8
Type
conf
DOI
10.1109/PESC.2001.954183
Filename
954183
Link To Document