• DocumentCode
    1590644
  • Title

    Unbalanced magnetic pull in cage induction motors with asymmetry in rotor structures

  • Author

    Arkkio, A.

  • Author_Institution
    Helsinki Univ. of Technol., Espoo, Finland
  • fYear
    1997
  • Firstpage
    36
  • Lastpage
    40
  • Abstract
    Rotor-cage faults, eccentric rotors or unsuitable numbers of rotor slots cause unbalanced magnetic pull in induction motors. The calculation of the forces is based on time-stepping, finite-element analysis of the magnetic field. The field is assumed to be two-dimensional, and the forces are calculated from the air-gap field using a method based on the principle of virtual work. The simulations done on a 30 kW two-pole motor and a 15 kW four-pole motor show that each of the three types of asymmetry can produce forces larger than the weights of the rotors
  • Keywords
    squirrel cage motors; 15 kW; 30 kW; air-gap field; cage induction motors; eccentric rotors; magnetic field analysis; magnetic forces; rotor structure asymmetry; rotor-cage faults; simulations; time-stepping finite-element analysis; unbalanced magnetic pull;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Electrical Machines and Drives, 1997 Eighth International Conference on (Conf. Publ. No. 444)
  • Conference_Location
    Cambridge
  • ISSN
    0537-9989
  • Print_ISBN
    0-85296-696-2
  • Type

    conf

  • DOI
    10.1049/cp:19971033
  • Filename