• DocumentCode
    1590687
  • Title

    Parameters and volt-ampere ratings of a field-oriented induction motor drive for flux-weakening applications

  • Author

    Bianchi, N. ; Bolognani, S.

  • Author_Institution
    Padova Univ., Italy
  • fYear
    1997
  • Firstpage
    46
  • Lastpage
    50
  • Abstract
    The purpose of this paper is to individuate the parameters of an induction motor (IM) and the volt-ampere ratings of the drive inverter to meet a desired torque-speed range, including the flux-weakening (FW) region. The study is performed assuming that a field-oriented control strategy is adopted. In such a way, the operating limits of the IM drive are readily carried out by the circle diagram widely used for permanent magnet synchronous motor drives. It is shown that different motor designs have to be developed according to whether the motor is operated only below the base speed or whether a FW region is also requested. Finally, a comparison with synchronous motor drives is included, pointing out the peculiar differences in motor dimensions and inverter size
  • Keywords
    induction motor drives; circle diagram; drive inverter; field-oriented control strategy; flux-weakening applications; induction motor drive; inverter size; motor designs; motor dimensions; motor parameters; torque-speed range; volt-ampere ratings;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Electrical Machines and Drives, 1997 Eighth International Conference on (Conf. Publ. No. 444)
  • Conference_Location
    Cambridge
  • ISSN
    0537-9989
  • Print_ISBN
    0-85296-696-2
  • Type

    conf

  • DOI
    10.1049/cp:19971035
  • Filename