DocumentCode :
1591336
Title :
Circuit modeling for PTS magnetically in sulated transmission lines
Author :
Shengyi Song ; Yongchao Guan
Author_Institution :
Key Lab. of Pulsed Power, Inst. of Fluid Phys., Mianyang, China
fYear :
2013
Firstpage :
1
Lastpage :
1
Abstract :
Summary form only given. PTS (Primary Test Stand) is an underway high-current accelerator for Z-pinch experiment in CAEP. In the paper a circuit model for its magnetically insulated transmission lines (MITLs) have been developed, in which all the PTS´s transmission line sections from water transmission lines, to vacuum insulator stack, to both outer and inner MITLs, and eventually to a wire array load, have been treated as a total of 273 transmission line elements with different transit time and impedance, among which comprise of 195 MITL elements. With aid of the model the performance of all these sections were predicted and discussed, including conducting current, interface voltage, loss current, flow impedance and grounded resistor of each MITL element, as well as the dynamic characteristics of the wire array load. The reliability and accuracy for all these predicted results will await for the examination of future experiments.
Keywords :
Z pinch; insulators; power transmission lines; resistors; wires (electric); CAEP; MITL elements; PTS magnetically insulated transmission lines; Z-pinch; circuit modeling; conducting current; flow impedance; grounded resistor; interface voltage; loss current; primary test stand; underway high-current accelerator; vacuum insulator stack; water transmission lines; wire array load;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Plasma Science (ICOPS), 2013 Abstracts IEEE International Conference on
Conference_Location :
San Francisco, CA
ISSN :
0730-9244
Type :
conf
DOI :
10.1109/PLASMA.2013.6634797
Filename :
6634797