DocumentCode :
1591859
Title :
Study on thermal insulation of double skin facade in Chengdu
Author :
Xu, Liang ; Zhang, Wanyi ; Wu, Zeling
Author_Institution :
College of Architecture and Environment, Sichuan University, Chengdu, China
fYear :
2012
Firstpage :
1
Lastpage :
4
Abstract :
The PBECA energy saving design application is used to study the energy consumption in summer for air conditioning of an office building with different transparent enclosing structures in Chengdu. The results show that the energy consumption in summer for air conditioning of building with double skin facade is 10% lower than that of building with other transparent enclosing structures. Compared with other enclosing structures, the room with the double glass facade facing west has the highest energy efficiency, and the room with the double skin facade facing south has the lowest energy efficiency.
Keywords :
building energy consumption; double skin façade; energy consumption level; transparent enclosing structure;