Abstract :
Diffusion tensor MRI is emerging as a rapid, nondestructive method to map myocardial fiber organization. A precise biological description of myocardial fiber performance requires knowledge of four variables: length, force, velocity and time. However, study of quantification of myocardial fiber length is lacking. The current study aims to show myocardial fiber length maps of formalin-fixed heats. Diffusion tensor MRI with medium diffusion resolution (15 directions) was performed in one isolated pig heart. Fiber length maps were investigated in multiple short-axis slices. The results provide supplementary information of myocardial fiber organization. To our knowledge, the present study is the first report of the myocardial fiber length mapping
Keywords :
biomedical MRI; cardiology; muscle; MR diffusion tensor imaging; formalin-fixed heats; isolated pig heart; myocardial fiber length mapping; myocardial fiber organization; Biomedical engineering; Biomedical imaging; Diffusion tensor imaging; Heart; Magnetic resonance imaging; Muscles; Myocardium; Radiology; Tensile stress; Transmission line matrix methods;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2005. IEEE-EMBS 2005. 27th Annual International Conference of the
Conference_Location :
Shanghai
Print_ISBN :
0-7803-8741-4
Type :
conf
DOI :
10.1109/IEMBS.2005.1616118
Filename :
1616118
Link To Document :
بازگشت