DocumentCode
1593358
Title
Vectorized Flaw Imaging by Arrayed Transmit-Receive Type ECT Probe
Author
Endo, Hisashi ; Takagi, Toshiyuki
Author_Institution
Inst. of Fluid Sci., Tohoku Univ., Sendai
fYear
2006
Firstpage
2538
Lastpage
2541
Abstract
This paper discusses an imaging of eddy current testing (ECT) data for surface breaking evaluation. The ECT probe used in this paper consists of transmit-receive (TR) type sensors as array elements to obtain the information on flaw directions, as well as deep situation. Switching two-directional scan modes gives two-dimensional vector mapping as ECT images. The ECT signals of the TR type sensor also give the information on flaw directions from their variation displayed on the complex number plane. Operating a complex number component of the signals visualizes directions of surface breaking
Keywords
array signal processing; eddy current testing; flaw detection; image processing; ECT images; eddy current testing; nondestructive testing; surface breaking evaluation; transmit-receive type sensor array; two-dimensional vector mapping; vectorized flaw imaging; Coils; Eddy current testing; Electrical capacitance tomography; Electromagnetic measurements; Image sensors; Inspection; Intelligent sensors; Probes; Sensor arrays; Surface cracks; Arrayed sensor type ECT probe; flaw imaging; transmit-receive sensor;
fLanguage
English
Publisher
ieee
Conference_Titel
SICE-ICASE, 2006. International Joint Conference
Conference_Location
Busan
Print_ISBN
89-950038-4-7
Electronic_ISBN
89-950038-5-5
Type
conf
DOI
10.1109/SICE.2006.314741
Filename
4108070