• DocumentCode
    1593624
  • Title

    Electrical machine failures, causes and cures

  • Author

    Botha, M. M Thys

  • Author_Institution
    LHMarthinusen, South Africa
  • fYear
    1997
  • Firstpage
    114
  • Lastpage
    117
  • Abstract
    The paper discusses the different failure mechanisms and some precautionary measures that can be put to use to prevent premature failure. The failure mechanisms discussed are: insulation system failure (moisture, vibration, over-temperature, system surges, over-speed, earthing practices); and mechanical failure (bearings failure, misalignment, air gap, out of balance, critical speed and resonance, corrosion)
  • Keywords
    electric machines; air gap; bearings failure; corrosion; critical speed; earthing practices; electrical machine failures; insulation system failure; mechanical failure; misalignment; moisture; out of balance; over-speed; over-temperature; premature failure prevention; resonance; system surges; vibration;