DocumentCode :
1594868
Title :
Study of liquid xenon scintillation for dark matter search
Author :
Neves, F. ; Chepel, V. ; Solovov, V. ; Pereira, A. ; Lopes, M.I. ; Da Cunha, J. Pinto ; Mendes, P. ; Lindote, A. ; Silva, C.P. ; Marques, R. Ferreira ; Policarpo, A.J.P.L.
Author_Institution :
Laboratorio de Instrumentacao e Fisica Exp. de Particulas, Coimbra, Portugal
fYear :
2005
Firstpage :
333
Lastpage :
336
Abstract :
The measurement of the scintillation efficiency for xenon nuclear recoils relative to that for 122 keV γ-rays is reported in the energy range from 5 keV to 140 keV. Prior to those measurements, the performance of the chamber with respect to the light collection efficiency, energy, time and position resolutions was assessed using 122 keV and 511 keV γ-rays.
Keywords :
astronomical instruments; cosmic ray apparatus; dark matter; gamma-ray detection; liquid ionisation chambers; liquid scintillation detectors; particle calorimetry; dark matter search; energy resolution; light collection efficiency; liquid xenon scintillation; position resolution; scintillation efficiency measurement; time resolution; xenon nuclear recoils; Cathodes; Computational fluid dynamics; Data acquisition; Energy measurement; Land surface temperature; Neutrons; Nuclear measurements; Photomultipliers; Solid scintillation detectors; Xenon;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Dielectric Liquids, 2005. ICDL 2005. 2005 IEEE International Conference on
Print_ISBN :
0-7803-8954-9
Type :
conf
DOI :
10.1109/ICDL.2005.1490093
Filename :
1490093
Link To Document :
بازگشت