DocumentCode :
1595346
Title :
A comparative analysis of methods for calculating the transient voltage distribution within the stator winding of an electric machine subjected to steep-fronted surge
Author :
Oyegoke, B.S.
Author_Institution :
Helsinki Univ. of Technol., Espoo, Finland
fYear :
1997
Firstpage :
294
Lastpage :
298
Abstract :
Three approaches are presented for predicting the magnitude and distribution of the transient voltages in the stator winding of an electric machine subjected to a steep-fronted surge. In this paper, multiconductor transmission line theory forms the basis of the three methods described. These methods utilise some aspects of the previous works to achieve simplification of solution without loss of accuracy. Indirect boundary integral equation method has been used to calculate the necessary capacitances in this analysis. Duality existing between the electric field and the magnetic field has been use to calculate the necessary inductances. Results predicted by these methods have been compared with experimental results. Recommendations for machines fed from a frequency converter are also included
Keywords :
electric machines; capacitance; electric field; frequency converter; indirect boundary integral equation method; inductances; machine insulation; magnetic field; multiconductor transmission line theory; stator winding; steep-fronted surge; transient voltage distribution; transient voltage magnitude;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Electrical Machines and Drives, 1997 Eighth International Conference on (Conf. Publ. No. 444)
Conference_Location :
Cambridge
ISSN :
0537-9989
Print_ISBN :
0-85296-696-2
Type :
conf
DOI :
10.1049/cp:19971086
Filename :
677134
Link To Document :
بازگشت