DocumentCode :
1596605
Title :
A new wattmeter for traceable power measurements at audio frequencies
Author :
Pickering, J.R. ; Wright, P.S.
Author_Institution :
Metron Designs Ltd., Alderford, UK
fYear :
1994
fDate :
11/2/1994 12:00:00 AM
Firstpage :
42552
Lastpage :
42555
Abstract :
Traceable power measurements have traditionally been provided at line frequencies (50 or 60 Hz). With the increased use of power electronics and the resulting use of higher frequencies in applications such as switched mode power supplies, instruments capable of power measurements to hundreds of kilohertz are now becoming available. In order to provide traceable calibrations for this new generation of wattmeters, NPL and Metron Designs Ltd. have developed the audio frequency wattmeter described in this paper
Keywords :
calibration; 50 to 60 Hz; Metron Designs; NPL; audio frequencies; audio frequency wattmeter; calibration; line frequencies; power electronics; switched mode power supplies; traceable power measurement;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Low Frequency Power Measurement and Analysis (Digest No. 1994/203), IEE Colloquium on
Conference_Location :
London
Type :
conf
Filename :
677203
Link To Document :
بازگشت