DocumentCode :
1596808
Title :
An improved strategy to detect the switching device fault in NPC inverter system
Author :
Lee, Jung-Dae ; Kim, Tae-Jin ; Lee, Jae-Chul ; Hyun, Dong-seok
Author_Institution :
Dept. of Electr. Eng., Hanyang Univ., Seoul
fYear :
2007
Firstpage :
132
Lastpage :
136
Abstract :
In this paper, a simple fault detection scheme is proposed for improving the reliability under the open-switch fault of a three-level neutral point clamped (NPC) inverter. The fault of switching device is detected by checking the change of a pole-voltage in a NPC inverter. This method has the advantages of fast detection ability and a simple realization for fault detection, compared with existing methods. Reconfiguration is also performed by two-phase control method that used to supply the balancing three-phase power to the load continuously. This proposed method minimizes a bad influence on the load caused by fault occurrence. This method can also be embedded into the existing NPC inverter system as a subroutine without excessive computational effort. The proposed scheme has been verified by simulation and experimental results.
Keywords :
fault diagnosis; invertors; machine control; phase control; reliability; switching convertors; NPC inverter system; pole-voltage; switching device fault detection; three-level neutral point clamped inverter; three-phase power balancing; two-phase control method; Circuit faults; Defense industry; Electrical fault detection; Fault detection; Fault diagnosis; Inverters; Power electronics; Power system reliability; Topology; Transformers;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics, 2007. ICPE '07. 7th Internatonal Conference on
Conference_Location :
Daegu
Print_ISBN :
978-1-4244-1871-8
Electronic_ISBN :
978-1-4244-1872-5
Type :
conf
DOI :
10.1109/ICPE.2007.4692363
Filename :
4692363
Link To Document :
بازگشت