• DocumentCode
    1599114
  • Title

    Remarx of the mevex X-ray machine

  • Author

    Jones, Andrew ; Briscall, S. ; Buck, J. ; Clough, Steve ; Cooper, G. ; Jeffries, Gary ; McLean, James ; Provis, Robert ; Raspin, Ron ; Rickard, L. ; Sinclair, M. ; Stevens, Andrew ; Webb, Kevin ; Williams, Tyson ; Wise, Steven

  • Author_Institution
    Pulsed Power Group, AWE, Aldermaston, UK
  • fYear
    2013
  • Firstpage
    1
  • Lastpage
    1
  • Abstract
    A replacement Marx generator for one of AWE´s flash radiographic machines is required to mitigate component obsolescence. The design uses twelve 250nF capacitors to charge a 14nF Blumlein to 700kV. For ease of maintenance the generator is removable from the oil tank by use of a rail system. Electrostatic codes have been used to design a new earthing system with access to the hidden capacitor terminals. The paper describes the design and the results of the Marx construction and high voltage commissioning into a resistive load. This paper builds upon design work presented at the IEEE UK Pulsed Power symposium 2011, to include results of construction and testing.
  • Keywords
    X-rays; pulse generators; pulsed power supplies; AWE flash radiographic machine; IEEE UK Pulsed Power symposium 2011; Marx construction; Marx generator; Mevex X-ray machine; capacitance 14 nF; capacitance 250 nF; earthing system; electrostatic code; hidden capacitor terminal; oil tank; rail system; voltage 700 kV; Aging; Capacitors; Fuel storage; Generators; Maintenance engineering; Radiography; Rails;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Plasma Science (ICOPS), 2013 Abstracts IEEE International Conference on
  • Conference_Location
    San Francisco, CA
  • ISSN
    0730-9244
  • Type

    conf

  • DOI
    10.1109/PLASMA.2013.6635102
  • Filename