DocumentCode :
1601215
Title :
Digital automatic calibration method for a time-interleaved ADCs system used in time-domain EMI measurement receiver
Author :
Slim, H.H. ; Russer, P.
Author_Institution :
Inst. for High Freq. Eng., Tech. Univ. Munchen, Munich, Germany
fYear :
2011
Firstpage :
476
Lastpage :
479
Abstract :
The sampling rate of state of the art analog to digital converters (ADCs) limits the base-band frequency range of real-time time domain electromagnetic interference (TD-EMI) measurement systems to 1 GHz. In this paper, a time interleaved sampling architecture is introduced to overcome this limitation and to extend the baseband of the time-domain EMI receiver. Using three parallel time-interleaved ADC converters a TD-EMI measurement system with 3 GHz base bandwidth has been realized. The misalignment effects are studied and an automatic calibration routine is introduced. The 40 dB spurious free dynamic range required by the CISPR standards is achieved.
Keywords :
analogue-digital conversion; calibration; electromagnetic interference; CISPR standards; analog to digital converters; automatic calibration routine; bandwidth 3 GHz; digital automatic calibration; real-time electromagnetic interference; sampling rate; time interleaved sampling architecture; time-domain EMI measurement receiver; time-interleaved ADC system; Calibration; Clocks; Electromagnetic interference; Frequency measurement; Receivers; Registers; Time domain analysis;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility (EMC), 2011 IEEE International Symposium on
Conference_Location :
Long Beach, CA, USA
ISSN :
2158-110X
Print_ISBN :
978-1-4577-0812-1
Type :
conf
DOI :
10.1109/ISEMC.2011.6038358
Filename :
6038358
Link To Document :
بازگشت