DocumentCode :
16016
Title :
A Novel Technique for Reducing Leakage Current by Application of Zero-Sequence Voltage
Author :
Ayano, Hideki ; Murakami, Kouhei ; Matsui, Yoshihiro
Author_Institution :
Dept. of Electr. Eng., Nat. Inst. of Technol., Tokyo, Japan
Volume :
51
Issue :
4
fYear :
2015
fDate :
July-Aug. 2015
Firstpage :
3094
Lastpage :
3100
Abstract :
This paper proposes a technique for reducing the leakage current flowing into a power source as a conducted noise. This leakage current may have an adverse effect on the peripheral equipment, e.g., causing malfunctions. The proposed technique requires us to add a zero-sequence voltage to the output voltage reference of the inverter. The zero-sequence voltage can be controlled without affecting the driving characteristics of the motor. In a motor drive range, a counter electromotive force increases with an increase in the motor speed. The proposed technique, therefore, controls the zero-sequence voltage as a function of the inverter output frequency; as a result, a stable motor drive and reduction in the common-mode current are realized simultaneously. Simulation and experimental results prove the validity of the proposed technique.
Keywords :
electric potential; invertors; leakage currents; motor drives; voltage control; common-mode current reduction; counter electromotive force; inverter; leakage current reduction; motor drive range; zero-sequence voltage control application; Harmonic analysis; Induction motors; Inductors; Integrated circuits; Inverters; Leakage currents; Resonant frequency; Common mode; EMI; common-mode; electromagnetic interference (EMI); leakage current; zero-sequence voltage;
fLanguage :
English
Journal_Title :
Industry Applications, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-9994
Type :
jour
DOI :
10.1109/TIA.2015.2391440
Filename :
7008475
Link To Document :
بازگشت