DocumentCode :
1602149
Title :
Impact of statistical parameter options on Reverberation Chamber test environment
Author :
Rajamani, V. ; Freyer, G.J.
Author_Institution :
Sch. of Electr. & Comput. Eng., Oklahoma State Univ., Stillwater, OK, USA
fYear :
2011
Firstpage :
665
Lastpage :
669
Abstract :
Electromagnetic compatibility immunity tests help to assure that electronic equipment will function properly in its operational electromagnetic environment. Several techniques are available to perform Standards compliance testing. All available techniques yield uncertainties in the immunity test results. The statistical isotropy of the electromagnetic environment in a Reverberation Chamber implies similar magnitude fields in any arbitrary direction providing an all aspect angle test that reduces some uncertainties in immunity testing. This paper addresses Reverberation Chamber uncertainties introduced by choices for specific statistical parameters.
Keywords :
electromagnetic compatibility; reverberation chambers; statistical analysis; electromagnetic compatibility immunity tests; electronic equipment; operational electromagnetic environment; reverberation chamber test environment; statistical isotropy; statistical parameter options; Electric fields; Electric variables measurement; Immunity testing; Reverberation chamber; Standards; Uncertainty;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility (EMC), 2011 IEEE International Symposium on
Conference_Location :
Long Beach, CA, USA
ISSN :
2158-110X
Print_ISBN :
978-1-4577-0812-1
Type :
conf
DOI :
10.1109/ISEMC.2011.6038393
Filename :
6038393
Link To Document :
بازگشت