Title :
Fast and accurate radiated susceptibility testing by using the reverberation chamber
Author_Institution :
Inf. Syst., Swedish Defence Res. Agency FOI, Linköping, Sweden
Abstract :
The reverberation chamber is a good tool to perform high level radiated susceptibility testing. The accuracy and repeatability is good, and the testing time is short. However, the susceptibility of electronic equipment depends on from which direction the equipment is irradiated. It has generally been assumed that the effect can not be included when performing a radiated susceptibility test in the reverberation chamber. In this paper we show the opposite, that it actually can be included.
Keywords :
electromagnetic wave polarisation; electronic equipment testing; reverberation chambers; electronic equipment susceptibility; radiated susceptibility testing; reverberation chamber; testing time; Electromagnetics; Radiation effects; Random variables; Reverberation chamber; Stress; Testing;
Conference_Titel :
Electromagnetic Compatibility (EMC), 2011 IEEE International Symposium on
Conference_Location :
Long Beach, CA, USA
Print_ISBN :
978-1-4577-0812-1
DOI :
10.1109/ISEMC.2011.6038429