  • Abstract
    This study proposes a new configuration consisting of two pairs of exciting magnetic coils and a pair of signal pickup electrodes with the higher driving frequencies than those of conventional electro-magnetic flowmeters. This rather complex configuration brings the meters a function of auto calibration and lowers the condition of the fluid conductivity. The analysis agrees well with experimental results and it clarifies the feasibility of the proposed configuration
  • Keywords
    calibration; eddy currents; electromagnetic devices; flowmeters; auto calibration; eddy currents; electromagnetic flowmeters; magnetic coils; signal pickup electrodes; Books; Calibration; Coils; Conductivity; Eddy currents; Electrodes; Frequency; Magnetic analysis; Magnetic field measurement; Measurement standards; Auto calibration; Electro-magnetic Flowmeter; High frequency excitation;
  • fLanguage